Source code for flexstack.management.dcc_adaptive

"""
Adaptive Decentralized Congestion Control algorithm and Gate Keeper.

Implements the adaptive approach specified in ETSI TS 102 687 V1.2.1 (2018-04)
clause 5.4 and the gate-keeping packet admission mechanism described in
Annex B.

Overview
--------
The adaptive algorithm (LIMERIC) maintains a smoothed estimate of the local
Channel Busy Ratio (``cbr_its_s``) and adjusts a *duty-cycle fraction*
parameter ``delta`` so that the ITS-S's own channel occupancy converges toward
a configurable target CBR.  ``delta`` represents the maximum fraction of the
wireless medium that this ITS-S is allowed to occupy over any given interval.

The :class:`DccAdaptive` class implements the five algorithmic steps of
clause 5.4 and is intended to be called at every UTC-modulo-200 ms boundary.

The :class:`GateKeeper` class implements the packet admission logic of Annex B.
It uses the current ``delta`` value to compute the earliest time at which the
next packet may be admitted to the access layer.  When ``delta`` is updated by
the adaptive algorithm, the gate-opening time is recalculated according to
equation B.2 to avoid synchronised transmissions across stations.
"""

from __future__ import annotations

from dataclasses import dataclass, field


[docs]@dataclass class DccAdaptiveParameters: """ Tunable parameters of the adaptive DCC algorithm. Default values are taken from Table 3 of ETSI TS 102 687 V1.2.1 (2018-04) clause 5.4. Attributes ---------- alpha : float Exponential averaging coefficient used in step 3 (equation 4). Default: 0.016. beta : float Proportional gain applied to the CBR error in step 2 (equations 2 and 3). Default: 0.0012. cbr_target : float Target Channel Busy Ratio toward which ``delta`` is steered. Default: 0.68. delta_max : float Hard upper bound on the duty-cycle fraction ``delta`` (step 4, equation 5). Corresponds to the maximum duty cycle permitted by ETSI EN 302 571. Default: 0.03. delta_min : float Hard lower bound on ``delta`` (step 5, equation 6). Prevents complete starvation under extreme congestion. Default: 0.0006. delta_up_max : float Upper clamp on the per-step offset when CBR is below the target (equation 2). Default: 0.0005. delta_down_max : float Lower clamp on the per-step offset when CBR is at or above the target (equation 3). Must be negative. Default: -0.00025. """ alpha: float = 0.016 beta: float = 0.0012 cbr_target: float = 0.68 delta_max: float = 0.03 delta_min: float = 0.0006 delta_up_max: float = 0.0005 delta_down_max: float = -0.00025
[docs]@dataclass class DccAdaptive: """ Adaptive DCC algorithm as specified in ETSI TS 102 687 V1.2.1 (2018-04) clause 5.4 (LIMERIC). The algorithm shall be evaluated at every UTC-modulo-200 ms boundary (clause 5.2). Each evaluation executes five ordered steps that update the duty-cycle fraction ``delta``: * **Step 1** – Compute a smoothed CBR estimate (``cbr_its_s``) from the two most recent local (or global, if available) CBR measurements. * **Step 2** – Compute a signed per-step correction (``delta_offset``) proportional to the distance between ``cbr_target`` and ``cbr_its_s``, clamped to ``[delta_down_max, delta_up_max]``. * **Step 3** – Apply an exponential filter to blend the new offset into the current ``delta``. * **Steps 4–5** – Clamp ``delta`` to ``[delta_min, delta_max]``. Parameters ---------- parameters : DccAdaptiveParameters, optional Algorithm tuning parameters. If not supplied the standard default values from Table 3 are used. Attributes ---------- cbr_its_s : float Current smoothed CBR estimate (initialised to 0.0). delta : float Current duty-cycle fraction (initialised to ``parameters.delta_min``). Examples -------- >>> alg = DccAdaptive() >>> delta = alg.update(cbr_local=0.5, cbr_local_previous=0.5) >>> 0.0006 <= delta <= 0.03 True """ parameters: DccAdaptiveParameters = field( default_factory=DccAdaptiveParameters ) cbr_its_s: float = field(default=0.0, init=False) delta: float = field(default=0.0, init=False) def __post_init__(self) -> None: self.delta = self.parameters.delta_min
[docs] def update( self, cbr_local: float, cbr_local_previous: float, cbr_global: float | None = None, cbr_global_previous: float | None = None, ) -> float: """ Execute one full adaptive DCC evaluation (steps 1–5 of clause 5.4). Parameters ---------- cbr_local : float Most recent local CBR measurement (``CBR_L_0_Hop``). cbr_local_previous : float Second most recent local CBR measurement (``CBR_L_0_Hop_Previous``). cbr_global : float or None, optional Most recent global CBR (``CBR_G``), received from a neighbouring ITS-S via GeoNetworking header as described in the NOTE of clause 5.4. When provided, replaces the local value in step 1. cbr_global_previous : float or None, optional Second most recent global CBR (``CBR_G_Previous``). When provided together with *cbr_global*, replaces the previous local value in step 1. Returns ------- float Updated ``delta`` value after clamping. Raises ------ ValueError If any CBR argument is outside ``[0.0, 1.0]``. """ for name, val in ( ("cbr_local", cbr_local), ("cbr_local_previous", cbr_local_previous), ): if not 0.0 <= val <= 1.0: raise ValueError( f"{name} must be in [0.0, 1.0], got {val!r}" ) p = self.parameters # Step 1 (equation 1) – CBR averaging # Use global CBR if both global measurements are available (NOTE 1). if cbr_global is not None and cbr_global_previous is not None: cbr_avg = (cbr_global + cbr_global_previous) / 2.0 else: cbr_avg = (cbr_local + cbr_local_previous) / 2.0 self.cbr_its_s = 0.5 * self.cbr_its_s + 0.5 * cbr_avg # Step 2 (equations 2–3) – compute delta_offset diff = p.cbr_target - self.cbr_its_s if diff > 0.0: # CBR below target → increase delta (more transmission allowed) delta_offset = min(p.beta * diff, p.delta_up_max) else: # CBR at or above target → decrease delta (fewer transmissions) delta_offset = max(p.beta * diff, p.delta_down_max) # Step 3 (equation 4) – exponential filter self.delta = (1.0 - p.alpha) * self.delta + delta_offset # Steps 4–5 (equations 5–6) – clamp to permitted range if self.delta > p.delta_max: self.delta = p.delta_max if self.delta < p.delta_min: self.delta = p.delta_min return self.delta
[docs]class GateKeeper: """ Packet admission gate keeper as described in ETSI TS 102 687 V1.2.1 (2018-04) Annex B. The gate keeper controls which packets may pass from the Network & Transport layer to the Access layer queue. The gate is **open** when the Access layer will accept a new packet and **closed** otherwise. Lifecycle --------- 1. A packet arrives at the gate. If the gate is open the packet is *admitted*: the gate closes and a gate-opening time ``t_go`` is scheduled using equation B.1. 2. From time ``t_go`` onward the gate is open again. 3. Whenever ``delta`` is updated by the adaptive algorithm, ``t_go`` is recalculated per equation B.2 to preserve relative ordering of gate openings without introducing synchronisation artefacts. The minimum inter-admission interval is 25 ms and the maximum is 1 s (both from the constraints in ETSI EN 302 571 referenced in Annex B). Parameters ---------- delta : float Initial duty-cycle fraction value obtained from :class:`DccAdaptive`. Attributes ---------- GATE_OPEN_MIN_INTERVAL_S : float Minimum allowed gate-open interval in seconds (25 ms). GATE_OPEN_MAX_INTERVAL_S : float Maximum allowed gate-open interval in seconds (1 s). Examples -------- >>> gk = GateKeeper(delta=0.01) >>> gk.is_open(t=0.0) True >>> admitted = gk.admit_packet(t=0.0, t_on=0.001) >>> admitted True >>> gk.is_open(t=0.0) False >>> gk.is_open(t=0.1) True """ GATE_OPEN_MIN_INTERVAL_S: float = 0.025 GATE_OPEN_MAX_INTERVAL_S: float = 1.0 _T_EPSILON: float = 1e-9 # 1 ns tolerance for floating-point rounding
[docs] def __init__(self, delta: float) -> None: """ Initialise the gate keeper with an initial ``delta`` value. Parameters ---------- delta : float Duty-cycle fraction from the adaptive DCC algorithm. """ self._delta: float = delta self._t_pg: float | None = None # time when gate last closed self._t_go: float | None = None # scheduled gate-opening time
# ------------------------------------------------------------------ # Public API # ------------------------------------------------------------------
[docs] def is_open(self, t: float) -> bool: """ Return ``True`` if the gate is currently open at time *t*. The gate is open on first use (before any packet has been admitted) and from ``t_go`` onward after each admission. Parameters ---------- t : float Current time in seconds. Returns ------- bool ``True`` if a packet may be admitted, ``False`` otherwise. """ if self._t_go is None: return True return t >= self._t_go - self._T_EPSILON
[docs] def admit_packet(self, t: float, t_on: float) -> bool: """ Attempt to admit one packet at time *t*. If the gate is open the packet is accepted, the gate closes, and the next gate-opening time is scheduled per equation B.1: .. math:: t_{go} = t_{pg} + \\min\\!\\left(\\max\\!\\left( \\frac{T_{on\\_pp}}{\\delta}, 0.025 \\right), 1 \\right) Parameters ---------- t : float Current time in seconds. t_on : float Transmission duration of this packet in seconds (``T_on_pp`` in Annex B). Returns ------- bool ``True`` if the packet was admitted; ``False`` if the gate was closed and the packet is rejected. Raises ------ ValueError If *t_on* is not positive. """ if t_on <= 0.0: raise ValueError(f"t_on must be positive, got {t_on!r}") if not self.is_open(t): return False self._t_pg = t interval = min( max(t_on / self._delta, self.GATE_OPEN_MIN_INTERVAL_S), self.GATE_OPEN_MAX_INTERVAL_S, ) self._t_go = t + interval return True
[docs] def update_delta(self, t: float, delta_new: float) -> None: """ Update the duty-cycle fraction and reschedule the gate-opening time. When ``delta`` changes, the gate-opening time is recalculated per equation B.2 to avoid synchronising gate openings across stations: .. math:: t_{go} = t_{pg} + \\min\\!\\left(\\max\\!\\left( \\frac{\\delta_{old}}{\\delta_{new}} \\cdot (t_{go} - t_{pg}), 0.025 \\right), 1 \\right) If the gate is currently open (no packet has been admitted yet, or ``t_go`` has already passed) only ``delta`` is updated. Parameters ---------- t : float Current time in seconds (used to determine whether the gate is still closed). delta_new : float Updated duty-cycle fraction from the adaptive DCC algorithm. Raises ------ ValueError If *delta_new* is not positive. """ if delta_new <= 0.0: raise ValueError(f"delta_new must be positive, got {delta_new!r}") delta_old = self._delta self._delta = delta_new # Gate is already open → no rescheduling needed if self._t_pg is None or self._t_go is None or self.is_open(t): return # B.2 – rescale remaining closed interval by delta ratio old_interval = self._t_go - self._t_pg new_interval = (delta_old / delta_new) * old_interval self._t_go = self._t_pg + min( max(new_interval, self.GATE_OPEN_MIN_INTERVAL_S), self.GATE_OPEN_MAX_INTERVAL_S, )