Adaptive Decentralized Congestion Control algorithm and Gate Keeper.
Implements the adaptive approach specified in ETSI TS 102 687 V1.2.1 (2018-04)
clause 5.4 and the gate-keeping packet admission mechanism described in
Annex B.
Overview
--------
The adaptive algorithm (LIMERIC) maintains a smoothed estimate of the local
Channel Busy Ratio (``cbr_its_s``) and adjusts a *duty-cycle fraction*
parameter ``delta`` so that the ITS-S's own channel occupancy converges toward
a configurable target CBR. ``delta`` represents the maximum fraction of the
wireless medium that this ITS-S is allowed to occupy over any given interval.
The :class:`DccAdaptive` class implements the five algorithmic steps of
clause 5.4 and is intended to be called at every UTC-modulo-200 ms boundary.
The :class:`GateKeeper` class implements the packet admission logic of Annex B.
It uses the current ``delta`` value to compute the earliest time at which the
next packet may be admitted to the access layer. When ``delta`` is updated by
the adaptive algorithm, the gate-opening time is recalculated according to
equation B.2 to avoid synchronised transmissions across stations.
"""
from __future__ import annotations
from dataclasses import dataclass, field
[docs]@dataclass
class DccAdaptiveParameters:
"""
Tunable parameters of the adaptive DCC algorithm.
Default values are taken from Table 3 of ETSI TS 102 687 V1.2.1 (2018-04)
clause 5.4.
Attributes
----------
alpha : float
Exponential averaging coefficient used in step 3 (equation 4).
Default: 0.016.
beta : float
Proportional gain applied to the CBR error in step 2
(equations 2 and 3). Default: 0.0012.
cbr_target : float
Target Channel Busy Ratio toward which ``delta`` is steered.
Default: 0.68.
delta_max : float
Hard upper bound on the duty-cycle fraction ``delta`` (step 4,
equation 5). Corresponds to the maximum duty cycle permitted by
ETSI EN 302 571. Default: 0.03.
delta_min : float
Hard lower bound on ``delta`` (step 5, equation 6). Prevents
complete starvation under extreme congestion. Default: 0.0006.
delta_up_max : float
Upper clamp on the per-step offset when CBR is below the target
(equation 2). Default: 0.0005.
delta_down_max : float
Lower clamp on the per-step offset when CBR is at or above the target
(equation 3). Must be negative. Default: -0.00025.
"""
alpha: float = 0.016
beta: float = 0.0012
cbr_target: float = 0.68
delta_max: float = 0.03
delta_min: float = 0.0006
delta_up_max: float = 0.0005
delta_down_max: float = -0.00025
[docs]@dataclass
class DccAdaptive:
"""
Adaptive DCC algorithm as specified in ETSI TS 102 687 V1.2.1 (2018-04)
clause 5.4 (LIMERIC).
The algorithm shall be evaluated at every UTC-modulo-200 ms boundary
(clause 5.2). Each evaluation executes five ordered steps that update the
duty-cycle fraction ``delta``:
* **Step 1** – Compute a smoothed CBR estimate (``cbr_its_s``) from the
two most recent local (or global, if available) CBR measurements.
* **Step 2** – Compute a signed per-step correction (``delta_offset``)
proportional to the distance between ``cbr_target`` and ``cbr_its_s``,
clamped to ``[delta_down_max, delta_up_max]``.
* **Step 3** – Apply an exponential filter to blend the new offset into the
current ``delta``.
* **Steps 4–5** – Clamp ``delta`` to ``[delta_min, delta_max]``.
Parameters
----------
parameters : DccAdaptiveParameters, optional
Algorithm tuning parameters. If not supplied the standard default
values from Table 3 are used.
Attributes
----------
cbr_its_s : float
Current smoothed CBR estimate (initialised to 0.0).
delta : float
Current duty-cycle fraction (initialised to ``parameters.delta_min``).
Examples
--------
>>> alg = DccAdaptive()
>>> delta = alg.update(cbr_local=0.5, cbr_local_previous=0.5)
>>> 0.0006 <= delta <= 0.03
True
"""
parameters: DccAdaptiveParameters = field(
default_factory=DccAdaptiveParameters
)
cbr_its_s: float = field(default=0.0, init=False)
delta: float = field(default=0.0, init=False)
def __post_init__(self) -> None:
self.delta = self.parameters.delta_min
[docs] def update(
self,
cbr_local: float,
cbr_local_previous: float,
cbr_global: float | None = None,
cbr_global_previous: float | None = None,
) -> float:
"""
Execute one full adaptive DCC evaluation (steps 1–5 of clause 5.4).
Parameters
----------
cbr_local : float
Most recent local CBR measurement (``CBR_L_0_Hop``).
cbr_local_previous : float
Second most recent local CBR measurement
(``CBR_L_0_Hop_Previous``).
cbr_global : float or None, optional
Most recent global CBR (``CBR_G``), received from a neighbouring
ITS-S via GeoNetworking header as described in the NOTE of
clause 5.4. When provided, replaces the local value in step 1.
cbr_global_previous : float or None, optional
Second most recent global CBR (``CBR_G_Previous``). When provided
together with *cbr_global*, replaces the previous local value in
step 1.
Returns
-------
float
Updated ``delta`` value after clamping.
Raises
------
ValueError
If any CBR argument is outside ``[0.0, 1.0]``.
"""
for name, val in (
("cbr_local", cbr_local),
("cbr_local_previous", cbr_local_previous),
):
if not 0.0 <= val <= 1.0:
raise ValueError(
f"{name} must be in [0.0, 1.0], got {val!r}"
)
p = self.parameters
# Step 1 (equation 1) – CBR averaging
# Use global CBR if both global measurements are available (NOTE 1).
if cbr_global is not None and cbr_global_previous is not None:
cbr_avg = (cbr_global + cbr_global_previous) / 2.0
else:
cbr_avg = (cbr_local + cbr_local_previous) / 2.0
self.cbr_its_s = 0.5 * self.cbr_its_s + 0.5 * cbr_avg
# Step 2 (equations 2–3) – compute delta_offset
diff = p.cbr_target - self.cbr_its_s
if diff > 0.0:
# CBR below target → increase delta (more transmission allowed)
delta_offset = min(p.beta * diff, p.delta_up_max)
else:
# CBR at or above target → decrease delta (fewer transmissions)
delta_offset = max(p.beta * diff, p.delta_down_max)
# Step 3 (equation 4) – exponential filter
self.delta = (1.0 - p.alpha) * self.delta + delta_offset
# Steps 4–5 (equations 5–6) – clamp to permitted range
if self.delta > p.delta_max:
self.delta = p.delta_max
if self.delta < p.delta_min:
self.delta = p.delta_min
return self.delta
[docs]class GateKeeper:
"""
Packet admission gate keeper as described in ETSI TS 102 687 V1.2.1
(2018-04) Annex B.
The gate keeper controls which packets may pass from the Network &
Transport layer to the Access layer queue. The gate is **open** when the
Access layer will accept a new packet and **closed** otherwise.
Lifecycle
---------
1. A packet arrives at the gate. If the gate is open the packet is
*admitted*: the gate closes and a gate-opening time ``t_go`` is
scheduled using equation B.1.
2. From time ``t_go`` onward the gate is open again.
3. Whenever ``delta`` is updated by the adaptive algorithm, ``t_go`` is
recalculated per equation B.2 to preserve relative ordering of gate
openings without introducing synchronisation artefacts.
The minimum inter-admission interval is 25 ms and the maximum is 1 s
(both from the constraints in ETSI EN 302 571 referenced in Annex B).
Parameters
----------
delta : float
Initial duty-cycle fraction value obtained from :class:`DccAdaptive`.
Attributes
----------
GATE_OPEN_MIN_INTERVAL_S : float
Minimum allowed gate-open interval in seconds (25 ms).
GATE_OPEN_MAX_INTERVAL_S : float
Maximum allowed gate-open interval in seconds (1 s).
Examples
--------
>>> gk = GateKeeper(delta=0.01)
>>> gk.is_open(t=0.0)
True
>>> admitted = gk.admit_packet(t=0.0, t_on=0.001)
>>> admitted
True
>>> gk.is_open(t=0.0)
False
>>> gk.is_open(t=0.1)
True
"""
GATE_OPEN_MIN_INTERVAL_S: float = 0.025
GATE_OPEN_MAX_INTERVAL_S: float = 1.0
_T_EPSILON: float = 1e-9 # 1 ns tolerance for floating-point rounding
[docs] def __init__(self, delta: float) -> None:
"""
Initialise the gate keeper with an initial ``delta`` value.
Parameters
----------
delta : float
Duty-cycle fraction from the adaptive DCC algorithm.
"""
self._delta: float = delta
self._t_pg: float | None = None # time when gate last closed
self._t_go: float | None = None # scheduled gate-opening time
# ------------------------------------------------------------------
# Public API
# ------------------------------------------------------------------
[docs] def is_open(self, t: float) -> bool:
"""
Return ``True`` if the gate is currently open at time *t*.
The gate is open on first use (before any packet has been admitted)
and from ``t_go`` onward after each admission.
Parameters
----------
t : float
Current time in seconds.
Returns
-------
bool
``True`` if a packet may be admitted, ``False`` otherwise.
"""
if self._t_go is None:
return True
return t >= self._t_go - self._T_EPSILON
[docs] def admit_packet(self, t: float, t_on: float) -> bool:
"""
Attempt to admit one packet at time *t*.
If the gate is open the packet is accepted, the gate closes, and the
next gate-opening time is scheduled per equation B.1:
.. math::
t_{go} = t_{pg} + \\min\\!\\left(\\max\\!\\left(
\\frac{T_{on\\_pp}}{\\delta}, 0.025
\\right), 1 \\right)
Parameters
----------
t : float
Current time in seconds.
t_on : float
Transmission duration of this packet in seconds
(``T_on_pp`` in Annex B).
Returns
-------
bool
``True`` if the packet was admitted; ``False`` if the gate was
closed and the packet is rejected.
Raises
------
ValueError
If *t_on* is not positive.
"""
if t_on <= 0.0:
raise ValueError(f"t_on must be positive, got {t_on!r}")
if not self.is_open(t):
return False
self._t_pg = t
interval = min(
max(t_on / self._delta, self.GATE_OPEN_MIN_INTERVAL_S),
self.GATE_OPEN_MAX_INTERVAL_S,
)
self._t_go = t + interval
return True
[docs] def update_delta(self, t: float, delta_new: float) -> None:
"""
Update the duty-cycle fraction and reschedule the gate-opening time.
When ``delta`` changes, the gate-opening time is recalculated per
equation B.2 to avoid synchronising gate openings across stations:
.. math::
t_{go} = t_{pg} + \\min\\!\\left(\\max\\!\\left(
\\frac{\\delta_{old}}{\\delta_{new}} \\cdot (t_{go} - t_{pg}),
0.025
\\right), 1 \\right)
If the gate is currently open (no packet has been admitted yet, or
``t_go`` has already passed) only ``delta`` is updated.
Parameters
----------
t : float
Current time in seconds (used to determine whether the gate is
still closed).
delta_new : float
Updated duty-cycle fraction from the adaptive DCC algorithm.
Raises
------
ValueError
If *delta_new* is not positive.
"""
if delta_new <= 0.0:
raise ValueError(f"delta_new must be positive, got {delta_new!r}")
delta_old = self._delta
self._delta = delta_new
# Gate is already open → no rescheduling needed
if self._t_pg is None or self._t_go is None or self.is_open(t):
return
# B.2 – rescale remaining closed interval by delta ratio
old_interval = self._t_go - self._t_pg
new_interval = (delta_old / delta_new) * old_interval
self._t_go = self._t_pg + min(
max(new_interval, self.GATE_OPEN_MIN_INTERVAL_S),