Skip to main content

T_GEN_CAM_DCC_MS

Constant T_GEN_CAM_DCC_MS 

Source
pub const T_GEN_CAM_DCC_MS: u64 = T_GEN_CAM_MIN_MS; // 100u64
Expand description

Default T_GenCam_DCC [ms] used until a DCC entity provides a value.

T_GenCam_DCC is the DCC-imposed minimum interval ∈ [T_GenCamMin, T_GenCamMax] (§6.1.2). Set it at runtime with CAMTransmissionManagement::set_t_gen_cam_dcc, typically from a DccEntity listener.